One guide per specification section: what the section covers, what the submittal must prove and where reviewers usually find problems.

Section 01 25 00 Substitution Procedures: when and how to propose another productWhen an MEP product counts as a substitution, the deadlines in Section 01 25 00, what the request must prove, and the costs it moves to the contractor.Section 01 33 00 Submittal Procedures: the rules every MEP submittal followsWhat Section 01 33 00 requires of every submittal: review periods, numbering, contractor review, deviations, resubmittals and why packages come back unreviewed.Section 22 11 19 Domestic Water Piping Specialties: backflow, mixing valves and the listings that matterThe ASSE listings, lead-free certifications and pressure losses to check on backflow preventers, mixing valves and water hammer arresters under 22 11 19.Section 22 34 00 Fuel-Fired Domestic Water Heaters: input, recovery and venting checksHow to check a gas water heater submittal under 22 34 00: input, efficiency, recovery at the design rise, ASME limits, venting category and gas pressure.Section 23 21 23 Hydronic Pumps: what the submittal must proveWhat Section 23 21 23 asks for, the 14 values to check on a hydronic pump submittal, how to read the curve, and the reasons pump submittals come back rejected.Section 23 33 00 Air Duct Accessories: fire and smoke damper ratings that pass inspectionChecking fire, smoke and combination damper submittals under 23 33 00: hourly rating, dynamic closure, UL 555S leakage class, temperature, actuators and access.Section 23 36 00 Air Terminal Units: checking VAV box submittals tag by tagHow to review VAV and fan-powered box submittals: minimum airflow the sensor can control, inlet static, sound, reheat coils and controls.Section 23 52 16 Condensing Boilers: efficiency at return temperature, turndown and flowReviewing a condensing boiler submittal: efficiency at the real return water temperature, turndown, minimum flow, venting, CSD-1 and gas pressure.Section 23 64 16 Centrifugal Water Chillers: capacity, kW per ton and IPLV on the submittalReviewing a centrifugal chiller submittal: capacity at design water temperatures, kW per ton, IPLV or NPLV, fouling factors, pressure drops and starter.Section 23 73 13 Modular Indoor Central-Station Air-Handling Units: fan, coil and casing checksHow to review an indoor air handler submittal: total static build-up, fan BHP, coil face velocity, casing leakage, drain pans, sound and shipping splits.Section 23 74 16.13 Packaged Rooftop Air-Conditioning Units: reviewing an RTU submittalHow to review a rooftop unit submittal: capacity at the project’s design conditions, IEER, fan static, economizer, refrigerant, curb and electrical data.Section 23 81 29 Variable Refrigerant Flow Systems: what a VRF submittal must proveReviewing a VRF submittal: connected capacity ratio, corrected capacity, piping limits, refrigerant concentration in small rooms and low-ambient heating.Section 26 24 16 Panelboards: ratings, breakers and fault current on the submittalReviewing panelboard submittals: voltage, bus and main ratings, interrupting rating against available fault current, series ratings, breaker types and spaces.Section 26 29 23 Variable-Frequency Motor Controllers: sizing, harmonics and bypassReviewing VFD submittals: size by motor current, not horsepower, SCCR, bypass type, IEEE 519 harmonics, motor lead length and inverter-duty motors.Section 26 32 13 Engine Generators: ratings, derates and NFPA 110 on the submittalReviewing a generator submittal: standby or prime rating, kW at site altitude, motor starting, NFPA 110 level and type, emissions tier, tank and sound.Section 26 51 19 LED Interior Lighting: what a fixture submittal must matchReviewing LED fixture submittals: delivered lumens and watts, CCT and CRI, driver and dimming protocol, voltage, emergency options and LM-79 data.

Bring us one submittal.

Send us one submittal and its spec section. We run the review with you, and you keep the report.

Run a pilot